Firing Loop For Passenger Front Airbag - Chery Tiggo 2009 Service Manual

Chery tiggo 2009 service manual
Table of Contents

Advertisement

DESCRIPTION
1: Rw - Wiring harness resistance
2: Rc - Contact coil resistance
3: Rs + Rt - Squib resistance + terminal resistance
4: Squib for passenger - side front airbag inflator
5: Contact coil
6: Wiring harness
7: HAE 3.5
R(DAB) = Rs + Rt + Rw
DTC Confirmation Procedure:
Before performing the following procedure, confirm that battery voltage is more than 12 V.
• Turn ignition switch off.
• Connect the X-431 scan tool to the Data Link Connector (DLC) - use the latest software available.
• Turn ignition switch on.
• With the scan tool, record and erase stored DTCs in the RCM.
• Turn ignition switch off and wait for a few seconds.
• Turn ignition switch on then select view DTC.
• If the DTC is detected, the DTC condition is current. Go to Diagnostic Procedure - Step 1.
• If the DTC is not detected, the DTC condition is intermittent (See Diagnostic Help and Intermittent DTC Trou-
bleshooting in Section 14 Restraints for more information).
Diagnostic Guide Lines
Observe the following guide lines while diagnosing this DTC:
• Troubleshoot any Engine Control Module (ECM) charging/cranking DTCs before proceeding.
• If the warning lamp goes out immediately after the warning lamp flashed for 6 - 7 seconds, this indicates that
the system is OK.
• If the warning lamp is on for 6 - 7 seconds continuously, then goes out, or the warning lamp is on continuously,
this indicates that there are history DTCs in the system. Use the Scan Tool to erase the DTCs.
• If any other condition occurs, use the Scan Tool to erase the history DTCs first, then check the warning lamp.
If the warning lamp does not go out immediately after the warning lamp flashes for 6 - 7 seconds when using
the Scan Tool, erase the history DTCs first.
• In the course of troubleshooting the airbag system, make sure the system power supply is shut off, and wait
two minutes for the system capacitor to discharge.
• The squib circuit connectors integrate a shorting spring (which prevents the airbag from deploying unintention-
ally due to static electricity by shorting the positive wire to the negative wire in the squib circuit when the con-
nectors are disconnected). Therefore, if the airbag electrical connector or spiral cable electrical connector is
damaged or improperly connected, the shorting spring may not be released when the electrical connector is
connected.
• The following tools are required to perform the DTC diagnostic procedure:
− X-431 Scan Tool
− Airbag Special Load Tool
− Digital Multimeter
NOTE :
While performing electrical diagnosis & testing, always refer to the electrical schematics for specific circuit
and component information.