PRODUCT SAFETY DATA SHEET
Océ North America, Inc.
Model
Description
Max. printing speed
Dimensions
Weight
Voltage
Frequency
Current-rated
Power consumption, low power
Power consumption, stand by
Power consumption, operation
EPA
E
NERGY
* Power consumption
Mains connection
Safety class
Protection class
Sound pressure level
(at bystander position)
Sound power level
Radio interference
Radiation
Heat emission
Dust concentration
Ozone emission
Room volume
Room ventilation
Use simulation at random
operation
Consumables
Additional safety information
Listed according to standard UL 60950-1 and CAN/CSA-C22.2 NO. 60950-1-03
Copyright © 2004 Océ-Technologies B.V., Venlo, NL
The content of this safety data sheet is subject to the disclaimer of
Note:
liability on page 312 of this manual.
Océ TDS860 printer engine
Electrophotographic printer, console model, plain paper, organic photoconductive drum,
powder toner.
13 m/min
Width
1720 mm
Depth
1146 mm
Height
1400 mm
240 V
60 Hz
21 A
4000 W
®
S
TAR
sleep mode
Cables with plug
I
IP 20
Standby
L
= 49 dB(A)
pA
L
= 64 dB(A)
WA
Complies with Directive 89/336/EEC and FCC rules and regulations, part 15 Class A.
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Standby 820 W; at continuous operation 4,0 kW
0,06 mg/m
0,02 mg/min at continuous operation
Recommendation: min. 75 m
Recommendation: min. 37,5 m
For heat evacuation extra ventilation may be necessary
Room volume and ventilation as recommended?
Daily copy volume (much more than average)
Total worktime
Ozone concentrations:
- Time weighted average
- Peak
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone
Odour Perception Limit for ozone
Océ OPC-Drum (Océ Safety Data Sheet E-259)
Océ E1 Toner (Océ Safety Data Sheet E-198)
Océ Copying Materials
The ozone filter does not have to be replaced to keep the ozone concentration in the
workplace below 0,04 mg/m
LISTED 927F
INFORMATION
TECHNOLOGY
EQUIPMENT
E 69871
939 kg
240 V 3ϕ
208 V 3ϕ
60 Hz
60 Hz
15/12/9 A
17/12/12 A
495 W
820 W
95 W (with controller and CRT)
(IEC 536) Protective earth connection
(IEC 529)
In operation
L
= 61 dB(A)
pA
L
= 76 dB(A)
WA
3
at continuous operation
3
3
/h (natural ventilation)
3
(i.e. the life of the filter equals that of the apparatus).
Number
Date
220 V 3ϕ
380 V 3ϕΝ
60 Hz
60 Hz
17/12/11 A
11/6/6 A
11/6/6 A
2
1200 m
8 h
3
< 0,001 mg/m
(< 0,0005 ppm)
3
0,0015 mg/m
( 0,0008 ppm)
?
3
0,2 mg/m
3
0,04 mg/m
EPA
E
NERGY
E-787-a-US
November 2004
415 V 3ϕΝ
60 Hz
(0,1 ppm)