Commands for Status Monitoring and Statistics

clear transceiver-test

clear transceiver-test
Description
Clears (resets) the transceiver test statistics.
NOTE
This command is available only on the "i" series modular switches.
Syntax Description
This command has no arguments or variables.
Default
N/A
Usage Guidelines
To display the transceiver test statistics, use the
following is sample output:
Transceiver system health diag result
Pass/Fail Counters Are in HEX
Slot
Cardtype Cardstate
----
-------- ---------
slot 1
Unknown
slot 2
Unknown
slot 3
FM8V
Operational MAC
slot 4
GM4X
Operational MAC
BPLNE
SMMI
Operational UART
BPLNE
SMMI
Operational FLASH
BPLNE
SMMI
Operational SRAM
BPLNE
SMMI
Operational NVRAM
BPLNE
SMMI
Operational ENET
BPLNE
Basbrd
Operational QUAKE
BPLNE
Basbrd
Operational TWISTER
Example
The following command clears (resets) all of the transceiver test statistics:
clear transceiver-test
History
This command was first available in ExtremeWare 6.2.2b108.
This command was not supported in ExtremeWare 7.0.
This command is supported in ExtremeWare 7.1.0.
672
show diagnostics sys-health-check
Test
Pass
----
-------- -------- --------------
2b81b
2b81b
2b81a
2b81a
2b81a
2b81a
2b81a
2b81a
2b81a
Fail Time_last_fail
0
0
0
0
0
0
0
0
0
ExtremeWare 7.7 Command Reference Guide