C. Image Formation System
1

Orientation of the Scanning Lamp

Install the scanning lamp so that the boss at the center (lamp
direction of the arrow (mirror mount reverse direction), and the longer side is positioned
so that the logo mark is at the front.
Note:
Do not touch the lamp assembly.
2

Position of the Blank Shutter Solenoid

Adjust the position of the solenoid to that A is 7.7 ±0.5 mm on both sides when the
solenoid is moved in the direction of activation. When taking measurements, be careful
not to force the shutter with calipers or the like.
After making adjustments, check to make sure that the solenoid moves smoothly.