Canon NP6330 Service Manual page 91

Hide thumbs Also See for NP6330:
Table of Contents

Advertisement

2) Fit the binding screw
mirror mount in place on the side plate.
3) Engage the scanner cable on the pulley and the hook as shown in the figure.
4) Remove the screw fitted in step 2).
COPYRIGHT © 1997 CANON INC.
(M4) in the screw hole of the pulley shaft, and fix the No. 2
Figure 3-519
=0~
3mm
Figure 3-520
CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 3 EXPOSURE SYSTEM
Put the steel
ball into the
hole of the
pulley.
Wind it eight
times.
Fix temporarily.
3-27