CHAPTER 11 TROUBLESHOOTING
7. Periodically Replaced Parts
Check the parts against the scheduled servicing chart and the periodically replaced
parts table. Replace the parts as necessary.
8. Others
Bringing a machine from a cold to warm place (from a warehouse to the site of
installation, for example) in winter can cause condensation to occur inside the machine,
leading to various problems; for example,
a. Condensation on the scanning system (glass, mirror, lens) can cause light images.
b. Condensation on the charging system can cause leakage.
c. Condensation on the pick-up/feeding guide can cause feeding faults.
If condensation is noted, dry-wipe the part or keep the machine powered for 60 min.
11-54
COPYRIGHT © 1997 CANON INC.
CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)