H. Optional Settings Mode [5]
To start optional settings mode, press '5' (keypad) and the OK key in sequence.
To select an item, press the number (keypad) and the OK key in sequence.
To change the setting, press the Zoom (+) / (-) key and the OK key.
To delete an item, press the Clear key.
A press on the Copy Start key while the service mode description is being
shown starts copying operation.
No.
Function
501
Use it to turn on/off the
auto power-off function.
502
Use it to switch the density
notation (9 < - - - - - - - > 17).
503
Use it to turn on/off the
size detection function.
504
Use it to change the upper
limit imposed on the copy
volume.
505
Use it to select U size
paper (G1).
506
Use it to select U size
paper (G2).
507
Use it to select U size
paper (G3).
508
Use it to select U size
paper (G4).
509
Use it to select cleaning
belt feeding length.
510
Use it to select the static
eliminator bias for
multifeeder pick-up.
COPYRIGHT © 1997 CANON INC.
Description
Enable/disable the function
as necessary.
Select either 9-level or 17-
level notation for the
density indicator LED.
Enable or disable the
original size detection
function as necessary.
Select from 1 to 100 to
change the upper limit.
Use it for G1 paper size.
Use it for G2 paper size.
Use it for G3 paper size.
Use it for G4 paper size.
Use it to switch between
standard and doubled
length.
As necessary, make a
switch-over so that the
voltage applied to the static
eliminator when picking up
from the multifeeder will
always be 4.0 kV.
CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 11 TROUBLESHOOTING
Remarks
on:Enable auto power-off.
off:Disable auto power-off.
0:9 level
1:17 level
on:Enable size detection.
off:Disable size detection.
1 to 100
• To change the setting,
press the number (key-
pad) and the OK key.
0:G-LTR
1:K-LGL
0:FOOLSCAP
1:OFFICIO
2:E-OFFICIO
3:A-LGL
4:A-OFFICIO
0:G-LGL
1:FOLIO
2:AUS FLS
0:LTR
1:A-LTR
0:Standard.
1:Double.
0:3 kV
1:4 kV