Basic Sequence; Basic Sequence Of Operation - Canon NP6330 Service Manual

Hide thumbs Also See for NP6330:
Table of Contents

Advertisement

CHAPTER 2 OPERATIONS AND TIMING
C. Basic Sequence

1. Basic Sequence of Operation

Power switch
ON
WMUP
Main motor (M1)
Fixing main heater (H1)
Fixing sub heater (H2)
Primary corona bias
Transfer corona bias
Static eliminator/
fixing roller bias
Scanning lamp (LA1)
Scanner
2-4
COPY START key
*1
175 c/347F
190 c/374F
ON
WMUPR
STBY
AER
*1: Fixing upper roller surface temperature.
Figure 2-103
COPYRIGHT © 1997 CANON INC.
INTR
SCFW
SCRV
Controlled to 190 c/374F
Forward
Reverse
CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
SCFW
SCRV LSTR
STBY