CHAPTER 4 IMAGE FORMATION SYSTEM
4) While butting the blade mount against the developing assembly, fix it in place with
two screws.
When installing the blade, place paper
the cylinder. (Tighten the screw while pushing on section A.)
Reference:
S-B is adjusted to 230 ±30 µm.
5. Installing the Electrode Positioning Plate
Install the electrode positioning plate while orienting it as shown in Figure 4-349.
4-48
Figure 4-348
Cylinder shaft
Figure 4-349
COPYRIGHT © 1997 CANON INC.
on the developing cylinder first to protect
Electrode positioning plate
CANON NP6330 REV.0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)