Displaying Power Domain Information - Juniper JUNOS OS 10.4 - PROTECTED SYSTEM DOMAIN Configuration Manual

Protected system domain configuration
Table of Contents

Advertisement

Action
Related
Documentation

Displaying Power Domain Information

Purpose
Action
Copyright © 2010, Juniper Networks, Inc.
Display the event log using the JCS management module CLI
The following sample output appears when the
most recent events:
system> displaylog —T mm[1]
1 I Audit
01/28/08 19:47:01 Remote logoff for 'gdickey' from Serial via COM1
2 I Blade_03 01/28/08 19:46:14 (bcgcpu3) Blade reboot
3 I SERVPROC 01/27/08 19:45:57 Login ID:''USERID' from 192.168.70.231.
4 E SERVPROC 01/27/08 19:42:58 Failure reading I2C device. Check bus 4.
5 I SERVPROC 01/27/08 19:41:54 Login ID:''USERID' from WEB browser at
IP@=192.168.70.231'
The sample output shows the event log for the JCS management module. By default,
the first time the command is executed, the five most recent log entries are displayed.
Each subsequent time the command is issued, the next five log entries are displayed.
The following sample output shows the complete event log for the JCS management
module. All events since the last time the log was cleared are shown.
system:mm[1]> displaylog -a
1 I Audit
01/28/08 19:47:01
2 I Blade_03 01/28/08 19:46:14 (bcgcpu3) Blade reboot
3 I SERVPROC 01/27/08 19:45:57 Login ID:''USERID' CLI telnet authenticated.
4 E SERVPROC 01/27/08 19:42:58 Failure reading I2C device. Check bus 4.
5 I SERVPROC 01/27/08 19:41:54 Login ID:''USERID' from WEB browser.
6 E SERVPROC 01/27/08 19:41:53 Blower 2 Fault Multiple blower failures.
7 E SERVPROC 01/27/08 19:41:53 Blower 1 Fault Single blower failure.
8 I SERVPROC 01/27/08 19:41:48 Ethernet[1] Link Established at 100Mb.
9 I SERVPROC 01/27/08 19:41:48 Ethernet[1] configured to do 100Mb/Full Duplex.
10 I SERVPROC 01/27/08 19:41:48 Ethernet[1] MAC Address: 0x00-09-6B-CA-0C-81
11 I SERVPROC 01/27/08 19:41:48 Ethernet[0] Link Established at 100Mb.
12 I SERVPROC 01/27/08 19:41:48 Ethernet[0] configured to do Auto Speed/Auto.
13 I SERVPROC 01/27/08 19:41:48 Ethernet[0] MAC Address: 0x00-09-6B-CA-0C-80
14 I SERVPROC 01/27/08 19:41:48 Management Module Network Initialization.
15 I SERVPROC 01/27/08 19:41:46 ENET[1] IP-Cfg:HstName=MM00096BCA0C81.
clearlog on page 211
displaylog on page 212
You can display power domain information to make sure the power domains are operating
properly. The JCS chassis is separated into two power domains. Power domain A supports
all JCS modules and slots (bays) 1 through 6. Power domain A uses power modules 1
and 2. Power domain B supports slots 7 though 14 and uses power modules 3 and 4.
NOTE: To support devices in power domain B, a power-supply option
(consisting of two power modules) must be installed.
Display power domain information using the JCS CLI
Chapter 15: Managing the JCS1200 Platform
command is targeted for the
displaylog
Remote logoff successful for user 'gdickey'
fuelg
command.
command:
displaylog
203