Ethernet Port Commands

link-fault-propagation group wait-to-shutdown

Configures the wait-to-shutdown timer value for the Link Fault Propagation (LFP) group. This is the
amount of time after all the source ports go down that LFP waits before shutting down the destination
ports.
link-fault-propagation group group_id wait-to-shutdown seconds
Syntax Definitions
group_id
seconds
Defaults
By default, the timer is set to zero (disabled).
Platforms Supported
OmniSwitch 6400, 6850, 6850E, 6855, 9000E
Usage Guidelines
Set the wait-to-shutdown timer value to 0 to disable the timer.
Make sure the LFP group specified with this command already exists in the switch configuration.
Example
-> link-fault-propagation group 1 wait-to-shutdown 40
-> link-fault-propagation group 3 wait-to-shutdown 70
-> link-fault-propagation group 5 wait-to-shutdown 0
Release History
Release 6.4.4; command introduced.
Related Commands
link-fault-propagation group
show link-fault-propagation
group
MIB Objects
alaLFPGroupTable
alaLFPGroupId
alaLFPGroupWaitToShutdown
alaLFPGroupRowStatus
OmniSwitch CLI Reference Guide
An existing LFP group ID number. The valid range is 1–8.
The number of seconds LFP waits before shutting down the destination
ports. The valid range is 0-300 in multiples of 5.
Configures an LFP group, including the administrative status.
Displays the LFP group configuration for the switch.