MVRP Commands

mvrp timer leave

Specifies the period of time that the switch has to wait in the Leave state before changing to the unregis-
tered state.
mvrp {port slot/port [– port2] | linkagg agg_num [-agg_num2]} timer leave timer-value
Syntax Definitions
slot/port
agg_num
timer-value
Defaults
parameter
timer-value
Platforms Supported
OmniSwitch 6400, 6850, 6855, 6850E, 9000E
Usage Guidelines
Use default timer settings unless there is a compelling reason to change the settings. Modifying timers
to inappropriate values might cause an imbalance in the operation of MVRP.
Leave timer value must be greater than or equal to twice the Join timer value, plus six times the timer
resolution (i.e. 16.66 milliseconds). Leave timer should be at least be greater than twice the join timer
plus100 milliseconds.
To use the agg_num parameter, the link aggregate group must be created and enabled.
Examples
-> mvrp port 1/2 timer leave 1800
-> mvrp port 1/2-12 timer leave 1800
-> mvrp linkagg 3 timer leave 1800
-> mvrp linkagg 3-6 timer leave 1800
Release History
Release 6.4.3; command was introduced.
OmniSwitch CLI Reference Guide
The slot number for the module and the physical port number on that
module (e.g., 3/1 specifies port 1 on slot 3).
The number corresponding to the aggregate group.
Specifies the value of the Leave Timer in milliseconds. The valid range
is 750 milliseconds to 2147483647 milliseconds.
default
1800 milliseconds