Gvrp Timer - Alcatel-Lucent OmniSwitch 6850-48 Cli Reference Manual

Alcatel-lucent omniswitch 6850-48: reference guide
Hide thumbs Also See for OmniSwitch 6850-48:
Table of Contents

Advertisement

GVRP Commands

gvrp timer

Configures the Join, Leave, or LeaveAll timer values for the switch ports.
gvrp timer {join | leave | leaveall} timer-value {linkagg agg_num | port slot/port}
no gvrp timer {join | leave | leaveall} {linkagg agg_num | port slot/port}
Syntax Definitions
join
leave
leaveall
timer-value
agg_num
slot/port
Defaults
parameter
timer-value (join)
timer-value (leave)
timer-value (leaveall)
Platforms Supported
OmniSwitch 6400, 6850, 6855, 6850E, 9000E
Usage Guidelines
Use the no form of this command to set the timer for a particular slot or port to the default value.
GVRP should be enabled on the port before configuring the timer value for that port.
Leave timer value should be greater than or equal to three times the Join timer value.
Leaveall timer value should be greater than or equal to the Leave timer value.
To use the agg_num parameter, the link aggregate group should be created and enabled.
OmniSwitch CLI Reference Guide
Specifies the value of the Join timer in milliseconds.
Specifies the value of the Leave timer in milliseconds.
Specifies the value of the LeaveAll timer in milliseconds.
The value of the specified timer in milliseconds. The valid range is
1–2,147,483,647 for Join timer, 3–2,147,483,647 for Leave timer, and
3–2,147,483,647 for LeaveAll timer.
The number corresponding to the aggregate group.
The slot number for the module and the physical port number on that
module (e.g., 3/1 specifies port 1 on slot 3).
default
600 ms
1800 ms
30000 ms
June 2012
page 10-11