Interfaces Violation-Recovery-Time - Alcatel-Lucent OmniSwitch 6850-48 Cli Reference Manual

Alcatel-lucent omniswitch 6850-48: reference guide
Hide thumbs Also See for OmniSwitch 6850-48:
Table of Contents

Advertisement

Ethernet Port Commands

interfaces violation-recovery-time

Configures the time interval after which the port is automatically re-activated if the port was shutdown for
any violation. This value is configurable on a global basis (applies to all ports on all modules) and on a
per-slot or per-port basis.
interfaces [slot | slot/port[-port2]] violation-recovery-time {seconds | default}
interfaces {slot | slot/port[-port2]} violation-recovery-time default
Syntax Definitions
slot
slot/port[-port2]
seconds
default
Defaults
By default, this command configures the global recovery time. The global value applies to all ports on
all modules in the switch.
By default, the violation recovery time is set to 300 seconds.
Platforms Supported
OmniSwitch 6400, 6850, 6850E, 6855, 9000E
Usage Guidelines
When the recovery timer expires, the interface is operationally re-enabled and the violation on the
interface is cleared.
The violation recovery time value does not apply to interfaces that are in a permanent shutdown state.
A port in this state is only recoverable using the interfaces clear-violation-all command.
The interface violation recovery mechanism is not supported on link aggregates, but is supported on
the link aggregate member ports.
Set the recovery time to 0 to disable this violation recovery mechanism.
Enter a slot number to configure the recovery time for all interfaces on a specific slot.
Enter a slot and port number or a range of ports to configure the recovery time for a specific interface
or a range of interfaces.
When this command is used to configure the recovery time for all ports on a slot or for a specific port
or range of ports, the value specified overrides the global maximum recovery time configured for the
switch.
OmniSwitch CLI Reference Guide
The slot number for a specific module.
The slot and port number (3/1). Use a hyphen to specify a range of ports
(3/1-3/10).
The number of seconds after which a port is reactivated. The valid range
is 30-600 seconds or specify 0 to disable the recovery timer.
Sets the recovery time to the global value for the specified ports. This
parameter is only available when a slot, port, or range of ports is speci-
fied with this command.
June 2012