Terminal Function Parameters: H

Multi-function Digital Inputs: H1
Param-
eter
Name
Number
Terminal S3
H1-01
Multi-function digital input 1
function selection
Terminal S4
H1-02
Multi-function digital input 2
function selection
Terminal S5
H1-03
Multi-function digital input 3
function selection
Terminal S6
H1-04
Multi-function digital input 4
function selection
Terminal S7
H1-05
Multi-function digital input 5
function selection
*1. The values in parentheses indicate initial values when initialized in 3-wire-sequence.
Multi-function Digital Input Functions
Setting
Value
0
3-wire sequence (Forward/Reverse Run command)
1
Local/Remote selection (ON: Operator, OFF: Parameter b1-01/b1-02 setting)
2
Operation Source Option Card/Inverter selection (ON: Parameter b1-01/b1-02 setting)
Multi-step speed reference 1
3
When H3-09 is set to 2, this function is combined with the master/auxiliary speed switch.
4
Multi-step speed reference 2
6
Jog frequency command (higher priority than multi-step speed reference)
7
Acceleration/Deceleration time selection 1
8
External baseblock NO (NO contact: Baseblock at ON)
9
External baseblock NC (NC contact: Baseblock at OFF)
A
Acceleration/deceleration ramp hold (ON: Acceleration/deceleration stopped, frequency is hold)
C
Multi-function analog input A2 enable (ON: Enable)
F
Terminal not used
10
UP command (Always set with the DOWN command)
11
DOWN command (Always set with the UP command)
12
FJOG command (ON: Forward run at jog frequency d1-17)
13
RJOG command (ON: Reverse run at jog frequency d1-17)
14
Fault reset (Reset when turned ON)
15
Emergency stop (NO: Deceleration to stop with deceleration time set in C1-09 when ON.)
17
Emergency stop (NC: Deceleration to stop with deceleration time set in C1-09 when OFF)
Timer function input
18
(times are set in b4-01 and b4-02 and the timer function outputs are set in H2-
19
PI control disable (ON: PI control disabled)
Parameters write enable
1B
(ON: All parameters can be set. OFF: All parameters are write protected.)
1C
Trim control increase (ON: d4-02 frequency is added to analog frequency reference.)
1D
Trim control decrease (ON: d4-02 frequency is subtracted from analog frequency reference.)
1E
Analog frequency reference sample/hold (ON: reference is sampled and hold)
Setting
Description
Range
0 to 82
0 to 82
0 to 82 3 (0)
0 to 82
0 to 82
Function
User Parameter Tables
Change
MEMO-
Factory
during
Access
BUS
Setting
Opera-
Level
Register
tion
24
No
A
400H
14
No
A
401H
*1
No
A
402H
*1
No
A
403H
4 (3)
*1
No
A
404H
6 (4)
.)
Page
Page
6-10
6-52
6-60
6-7
6-7
6-7
6-15
6-53
6-53
6-54
6-53
6-55
6-55
6-62
6-62
7-2
6-14
6-14
6-86
6-87
6-117
6-58
6-58
6-59
5-23