Adjusting the Meter
The influence of the settings of gain and bias on the analog outputs is shown on three examples in
6-68
Output Voltage
Gain: 170%
Bias: 30%
10V
3V
0V
0%
Fig 6.49 Monitor Output Adjustment
Gain: 100%
Bias: 0%
Gain: 0%
Bias: 100%
Monitor Item
100%
(e.g. Output Frequency)
Fig
6.49.