Register No.
0019H
001AH
001BH
0020H
6-80
Alarm Content 1
Bit 0
UV, DC bus undervoltage
Bit 1
OV, DC bus overvoltage
Bit 2
OH, Inverter heatsink overheat pre-alarm
Bit 3
OH2, Inverter overheat alarm input by a digital input
Bit 4
OL3, Overload detection 1
Bit 5
Not used
Bit 6
EF, Forward/Reverse input set at the same time
Bit 7
BB, Baseblock active
Bit 8
EF3, External alarm set on terminal S3
Bit 9
EF4, External alarm set on terminal S4
Bit A
EF5, External alarm set on terminal S5
Bit B
EF6, External alarm set on terminal S6
Bit C
EF7, External alarm set on terminal S7
Bit D/E
Not used
Bit F
Not used
Alarm Content 2
Bit 0
Not used
Bit 1
Not used
Bit 2
OPR, Digital operator disconnected
Bit 3
CE, Memobus communications error
Bit 4
BUS, Bus option communications error
Bit 5
CALL, Communications on standby
Bit 6
OL1, Motor overload
Bit 7
OL2, Inverter overload
Bit 8 to A
Not used
Bit B
FBL, PI feedback loss
Bit C
CALL, Communications on standby
Bit D
UL3, Loss of Load detection
Bit E
Not used
Bit F
Not used
Alarm Content 3
Bit 0
Not used
Bit 1
OH3, Motor overheat pre-alarm
Bit 2 to F
Not used
Inverter status
Bit 0
Forward operation
Bit 1
Reverse operation
Bit 2
Inverter startup complete
Bit 3
Fault
Bit 4
Data setting error
Bit 5
Multi-function digital output 1 (terminal M1 - M2)
Bit 6
Multi-function digital output 2 (terminal M3 - M4)
Bit 7
Not used
Bits 8 to F
Not used
Contents
1: Completed 2: Not completed
1: Fault
1: Error
1: ON 0: OFF
1: ON 0: OFF