Time Charts
The following table shows the time charts for each of the speed agreement functions.
6-26
Related parameter
f
= f
Agree
ref
out
Freq. Ref.
Output
Frequency
f
= f
Agree
ref
out
f
= f
Agree
ref
out
(Multi-function output setting = 2)
f
= f
Agree
out
set
(ON at the following conditions during frequency agree)
Output
Frequency
f
= f
Agree
out
set
f
= f
Agree 1
out
ref
(Multi-function output setting = 3)
Frequency (FOUT) Detection 1
(L4-01 > | Output frequency |)
Output
Frequency
Freq. Detection 1
(Multi-function output setting = 4)
Frequency
Detection
Frequency (FOUT) Detection 2
(L4-01 < | Output frequency |)
Output
Frequency
Freq. Detection 2
(Multi-function output setting = 5)
L4-01: Speed Agree Level
L4-02: Speed Agree Width
L4-02
Freq. Ref.
L4-02
OFF
ON
L4-02
L4-01
L4-01
L4-02
ON
OFF
L4-02
L4-01
L4-01
L4-02
ON
OFF
L4-02
L4-01
L4-01
L4-02
OFF
ON

Hide quick links: