Writing Parameter Set Values Stored in the Digital Operator to the Inverter (COPY)
To write parameter set values stored in the Digital Operator to the Inverter, use the following method.
Digital Operator Display
Step
No.
LED Digital Operator
1
2
3
4
5
6
7
If a fault is displayed press any key to clear the fault display and return to the o3-01 display. Fault displays and
their meanings are shown on the following page.
LCD/HOA Digital Operator
-ADV-
** Main Menu **
Press the MENU key until the Advanced Pro-
gramming Mode is reached.
Programming
-ADV-
Press the DATA/ENTER key to enter the Func-
Initialization
tion Selection Display in Advanced Program-
A1
- 00 = 1
ming Mode.
Select Language
-ADV-
Scroll to parameter o3-01 (Copy Function
COPY Function
Selection) using the Increment key and Decre-
o3
- 01 = 0
ment key.
Copy Funtion Sel
-ADV-
Copy Function Sel
Press the DATA/ENTER key to enter the
o3-01=
0
*0*
Parameter Setting Display.
COPY SELECT
-ADV-
Copy Function Sel
Change the set value to 2 using the Increment
o3-01=
2
*0*
key.
OP
INV WRITE
-ADV-
COPY
Press the DATA/ENTER key. The COPY func-
INV COPYING
OP
tion will start.
-ADV-
COPY
If the COPY function is completed "End"
COPY COMPLETE
respectively "Copy Complete" is displayed on
the Digital Operator. Then the display returns to
the Monitor Display and parameter o1-03 is
-ADV-
Copy Function Sel
automatically reset to 0.
o3 -
01
=0
*0*
COPY SELECT
Digital Operator Functions