Using the Timer Function

The digital input and output terminals can be used with a timer function: A digital output is switched ON with
a set delay time after a digital input has been switched ON.
Related Parameters
Param-
eter
Number
Timer function ON-delay
b4-01
time
Timer function OFF-delay
b4-02
time
Multi-Function Digital Inputs (H1-01 to H1-05)
Set Value
18
Multi-Function Digital Outputs (H2-01 to H2-02)
Set Value
12
Setting Example
When the timer function input remains switched ON for a time longer than the setting in b4-01, the timer out-
put function is turned ON. When the timer function input remains switched OFF for a time longer than the set-
ting in b4-02, the timer output function is turned OFF. An example of timer function operation is given in the
following diagram.
Timer function input
Timer function output
6-86
Name
Set the timer function output ON delay time (dead
time) for the timer function input in 1-second units.
Enabled when a timer function is set in H1-
and H2-
.
Set the timer function output OFF delay time (dead
time) for the timer function input in 1-second units.
Enabled when the timer function is set in H1-
and H2-
.
Timer function input
Timer function output
Fig 6.55 Timer Function Operation Example
Setting
Description
Range
0.0 to
300.0
0.0 to
300.0
Function
Function
Change
Factory
during
Access
Setting
Opera-
Level
tion
0.0 sec.
No
A
0.0 sec.
No
A