Displaying and Changing Setting Values

5-1

Displaying and Changing Setting Values

5-1-1 Displaying Setting Values

Basic Model
Process value
Maximum value
Minimum value
Set Value LED Display Model

5-1-2 Changing Setting Values

80
· When the Mode Key is pressed in RUN mode, the K3NP displays a setting val-
ue on the PV display (in the order of HH, H, L, and LL).
· While the setting value is displayed, the corresponding SV display status indi-
cator is lit.
· Unless another operation key is pressed within five seconds after the setting
value is displayed, the process, maximum, or minimum value is displayed
again.
HH is lit.
H is lit.
HH setting
H setting
value
value
No key input
for 5 seconds.
· The setting value appears on the SV display and the corresponding SV display
status indicator is lit while the process, maximum, or minimum value is dis-
played on the PV display
· When the Mode Key is pressed, the K3NP displays a setting value (in the order
of HH, H, L, and LL) on the SV display.
· Setting values can be prohibited against change when key protect or setting
value change prohibit is ON in protect mode.
· Select the setting value to be changed with the Mode Key.
· All digits will be displayed and ready for changing if the Shift Key is pressed.
· Press the Up and Shift Keys to change the displayed setting value. The input
will be entered if nothing else is input within five seconds. The input is entered
immediately by pressing the Mode Key.
· The next setting value will be displayed and ready for changing if the Mode Key
is pressed. If nothing else is input within five seconds, the setting value will be
entered and the previous setting value will be displayed.
· The setting value can be changed through communications if the K3NP is a
model with a communications function.
L is lit.
L setting
value
No key input
No key input
for 5 seconds.
for 5 seconds.
Section 5-1
LL is lit.
LL setting
value
No key input
for 5 seconds.