Omron CX-INTEGRATOR V2 - 12-2009 Operation Manual page 64

Table of Contents

Advertisement

1-5
Window Descriptions
1-5-2
Main Window
Communications Unit and Port Information for Target PLC
The following CPU Unit built-in serial ports, Inner Boards, and Communications Units
(referred to here as Communications Units/Ports) that are part of the target PLC are
displayed under TargetPLC in directory tree format.
CPU port [CJ1M-CPU22] Net (−) Node (2) Unit (0)
Connection status
: Not connected (access not possible)
: Connected (access possible)
Description:
Communications
1) Right of
Unit/port
CPU Unit built-in
CPU Unit/port
serial port
Serial port on
Serial Communications
Inner Board
Board
(Nothing
displayed if an
Inner Board is not
mounted.)
Communications
Communications Unit
Unit name, Model
name (Ethernet Unit,
Controller Link Unit,
SYSMAC LINK Unit, or
DeviceNet Unit)
CompoNet Master Unit
name
If a connection is established and access is enabled for a Communications Unit/port,
the icon on the left will be
Right-click the Communications Unit/port and select Connect to connect to the
Communications Unit/port and enable access. (With the CX-Integrator, only one
Communications Unit/port can be accessed at any one time.)
The actual network configuration can then be uploaded by right-clicking the
Communications Unit/port and selecting Transfer
1-36
or
:
2) Unit model
Unit name
Target PLC's
CPU Unit
model
Serial Com-
munications
Board model
Communicatio
ns Unit model
3) Network address
The network address
(1 to 127, decimal),
when the serial port is
registered in the local
network table to treat
it as a network.
Note: "−" will be
displayed if the
serial port is not
registered in the
local network
table.
Same as above.
Network address (1 to
127, decimal)
Note: "−" will be
displayed if a local
network table is not
registered.
− (Does not change.)
instead of
.
Network to PC.
5) Unit number of FINS unit address
4) Node address
3) Network address
2) Unit model
1) Unit name
4) Node
5) Unit number or
address
FINS unit address
− (Does not
Serial port's FINS
change.)
unit address
(decimal)
Peripheral port: 253
RS-232C port: 252
Note: "−" will be
displayed if
the serial port
is not
registered in
the local
network
table.
− (Does not
Serial port's FINS
change.)
unit address
(decimal)
Port 1: 225
Port 2: 226
Note: "−" will be
displayed if
the serial port
is not
registered in
the local
network
table.
Node
Unit number
address
(decimal)
(node ID on
(Rotary switch on
the network)
front of CPU Bus
Unit: 0 to 15)
− (Does not
Unit number
change.)
(decimal)
(Master Unit rotary
switch number: 0 to
99)

Hide quick links:

Advertisement

Table of Contents
loading