3-2 Setting the Routing Tables
3-2-2 Creating the FINS Local Routing Tables
Note: For an Inner Board, the Special I/O Unit number of the Board itself is 225, but the Special
CPU Unit's Built-in Serial Port:
Right-click the Unit 225 or Unit 252 icon and select Insert CPU SIOU.
3. The Enter SIOU Details Dialog Box will be displayed.
Set the serial port's local network address in the Local Network Number Field and
click the OK Button.
The local network table will be registered for the serial port.
3-16
Click the SIOU Tab
I/O Unit numbers of the ports are 228 for port 1 and 229 for port 2.
Click the SIOU Tab.
When the local network table is set for the
CPU Unit's built-in serial port, the serial
port
can
be
set
instead
of
the
Communications Unit's unit number.
When the local network table is set for the
Serial Communication Board/Unit's serial port,
the serial port can be set instead of the
Communications Unit's unit number.