Pulse Outputs
5-2-3

Pulse Output Terminal Allocations

Lower Terminal Block
(Example: Transistor Outputs)
Pulse output 0 (CCW/direction/PWM output 0)
Pulse output 0 (CW/pulse)
Lower Terminal Block
(Example: Transistor Outputs)
Pulse output 0 (CCW/direction/PWM output 0)
Pulse output 0 (CW/pulse)
Lower Terminal Block
(Example: Transistor Outputs)
Pulse output 0 (CCW/direction/PWM output 0)
Pulse output 0 (CW/pulse)
The following diagrams show the terminals that can be used for pulse outputs
in each CPU Unit.
■ CPU Unit with 14 I/O Points
NC
00
01
02
NC
COM COM COM
CIO 100
■ CPU Unit with 20 I/O Points
NC
00
01
02
NC
COM COM COM
CIO 100
■ CPU Unit with 30 I/O Points
NC
00
01
02
NC
COM COM COM
CIO 100
Pulse output 1 (CW/pulse)
Origin search 0
(Error counter reset output)
NC
04
05
NC
COM
03
Pulse output 1 (CCW/direction/PWM output 1)
Pulse output 1 (CW/pulse)
Origin search 0
(Error counter reset output)
07
04
05
COM 06
03
Pulse output 1 (CCW/direction/PWM output 1)
Pulse output 1 (CW/pulse)
Origin search 0 (Error counter reset output)
Origin search 1 (Error counter reset output)
07
04
05
00
COM
03
06
01
COM
CIO 101
Pulse output 1 (CCW/direction/PWM output 1)
Section 5-2
Origin search 1
(Error counter reset output)
Origin search 1
(Error counter reset output)
02
03
181