High-Speed Counter/Pulse Output Instructions; Ini - Omron SYSMAC CP Series Instruction & Reference Manual

Cpu unit
Hide thumbs Also See for SYSMAC CP Series:
Table of Contents

Advertisement

2 Instructions
High-speed Counter/Pulse Output
Instructions

INI

Mne-
Instruction
monic
MODE CONTROL
INI
Symbol
Applicable Program Areas
Area
Usage
Operands
Operand
P
Port specifier
C
Control data
NV
First word with new PV
P: Port Specifier
P
0000 hex
Pulse output 0
0001 hex
Pulse output 1
0010 hex
High-speed counter 0
0011 hex
High-speed counter 1
0012 hex
High-speed counter 2
0013 hex
High-speed counter 3
0014 hex
High-speed counter 4
0015 hex
High-speed counter 5 (Cannot be used in CP1E-E10D - )
1000 hex
PWM(891) output 0
2-308
Varia-
Function
tions
code
@INI
880
Step program areas
OK
Description
Function
INI(880) can be used to execute the following operations
• To start comparison with the high-speed counter comparison table
• To stop comparison with the high-speed counter comparison table
• To change the PV of the high-speed counter.
• To change the PV of interrupt inputs in counter mode.
• To change the PV of the pulse output (origin fixed at 0).
• To stop pulse output.
INI
INI(880)
P
P: Port specifier
C
C: Control data
NV
NV: First word with new PV
Subroutines
OK
Port
CP1E CPU Unit Instructions Reference Manual(W483)
Interrupt tasks
OK
Data type
Size
WORD
1
UINT
1
DWORD
2