Auxiliary Area Allocations by Address
Addresses
Name
Word
Bits
A540
A540.10 Pulse Out-
put 0 Posi-
tioning
Completed
Signal
A541
A541.00 Pulse Out-
put 1 Reset
Bit
A541.08 Pulse Out-
put 1 CW
Limit Input
Signal Flag
A541.09 Pulse Out-
put 1 CCW
Limit Input
Signal Flag
A541.10 Pulse Out-
put 1 Posi-
tioning
Completed
Signal
A562
A562.00 Error
Counter 0
Reset Bit
A562.01 Error
Counter 0
Disable Bit
A563
A563.00 Error
Counter 1
Reset Bit
A563.01 Error
Counter 1
Disable Bit
A580
A580.00
FB Commu-
to
nications
A580.03
Instruction
Retries
A581
All
FB Commu-
nications
Instruction
Response
Monitoring
Time
Function
This is the positioning completed
input signal used in the origin search
for pulse output 0. The input signal
from the servo driver is output to this
bit from the ladder program to enable
using the signal.
The pulse output 1 PV (contained in
A278 and A279) will be cleared when
this bit is turned ON.
This is the CW limit input signal for
pulse output 1, which is used in the
origin search. To use this signal,
write the input from the actual sensor
as an input condition in the ladder
program and output the result to this
flag.
This is the CCW limit input signal for
pulse output 1, which is used in the
origin search. To use this signal,
write the input from the actual sensor
as an input condition in the ladder
program and output the result to this
flag.
This is the positioning completed
input signal used in the origin search
for pulse output 1. The input signal
from the servo driver is output to this
bit from the ladder program to enable
using the signal.
Turn ON this bit to reset the Error
Counter 0 Present Value and turn
OFF the Error Counter 0 Error Flag.
Turn ON this bit to hold the present
value of error counter 0.
Turn ON this bit to reset the Error
Counter 1 Present Value and turn
OFF the Error Counter 0 Error Flag.
Turn ON this bit to hold the present
value of error counter 1.
Automatically stores the number of
retries in the FB communications
instruction settings specified in the
PLC Setup.
Automatically stores the FB commu-
nications instruction response moni-
toring time set in the PLC Setup.
Settings
Status
Status at
after
startup
mode
change
---
Retained Cleared
---
Retained Cleared
---
Retained Cleared
---
Retained Cleared
---
Retained Cleared
---
---
Cleared
ON: Error
---
Cleared
counter value
held.
OFF: Error
counter value
not held.
---
---
Cleared
ON: Error
---
Cleared
counter value
held.
OFF: Error
counter value
not held.
0 to F hex
---
Cleared
0001 to FFFF
---
Cleared
hex (Unit: 0.1 s;
Range: 0.1 to
6553.5)
0000 hex: 2 s
Appendix D
Write
Related
timing
Flags,
Settings
---
---
A278 and
A279
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Written at
start of
operation
Written at
---
start of
operation
567