Auxiliary Area Allocations by Function
Modbus-RTU Easy Master Information (CP1L CPU Units with L CPU Type)
Name
Serial Port 1 Modbus-RTU
Master Execution Bit
Serial Port 1 Modbus-RTU
Master Execution Normal
Flag
Serial Port 1 Modbus-RTU
Master Execution Error Flag
Note
DM fixed allocation words for Modbus-RTU Easy Master for serial port 2: D32300 to D32399
Instruction-related Information
Name
Step Flag
Macro Area Input Words
Macro Area Output Words
Function Block Information
Function Block Memory Information
Name
FB Program Data Flag
OMRON FB Library Information
Name
FB Communications Instruc-
tion Response Required
FB Communications Instruc-
tion Port No.
FB Communications Instruc-
tion Retries
FB Communications Instruc-
tion Response Monitoring
Time
FB DeviceNet Communica-
tions Instruction Response
Monitoring Time
Note
These Auxiliary Area bits/words are not to be written by the user. The number of resends and response monitoring time must be
set by the user in the FB communications instructions settings in the PLC Setup, particularly when using function blocks from the
OMRON FB Library to execute FINS messages or DeviceNet explicit messages communications. The values set in the Settings for
528
Address
A640.00
Turn ON this bit to send a command and receive a
response for serial port 2 using the Modbus-RTU easy
master function.
This bit will be turned OFF automatically by the system
when communications have been completed.
Turned ON: Execution started
ON: Execution in progress.
OFF: Not executed or execution completed.
A640.01
ON when one command has been sent and the
response received for serial port 2 using the Modbus-
RTU easy master function.
ON: Execution normal.
OFF: Execution error or still in progress.
A640.02
ON when an error has occurred in communications for
serial port 2 using the Modbus-RTU easy master func-
tion. The error code is output to D32252 in the DM fixed
allocation words for Modbus-RTU Easy Master.
ON: Execution error.
OFF: Execution normal or still in progress.
Address
A200.12
ON for one cycle when step execution is started with
STEP(008).
A600 to
Before the subroutine specified in MCRO(099) is exe-
A603
cuted, the source words for the subroutine are trans-
ferred to A600 through A603 (input parameter words).
A604 to
After the subroutine specified in MCRO(099) has been
A607
executed, the results of the subroutine are transferred
from A604 through A607 to the specified destination
words (output parameter words).
Address
A345.00
Turns ON if the FB program memory contains FB pro-
gram data.
OFF: No data
ON: Data present
Address
A580.15
0: Not required
1: Required
A580.08 to
0 to 7 hex: Communications port No. 0 to 7
A580.11
F hex: Automatic allocation
A580.00 to
Automatically stores the number of retries in the FB com-
A580.03
munications instruction settings specified in the PLC
Setup.
A581
Automatically stores the FB communications instruction
response monitoring time set in the PLC Setup.
0001 to FFFF hex (Unit: 0.1 s; Range: 0.1 to 6553.5)
0000 hex: 2 s
A582
Automatically stores the FB DeviceNet communications
instruction response monitoring time set in the PLC
Setup.
0001 to FFFF hex (Unit: 0.1 s; Range: 0.1 to 6553.5)
0000 hex: 2 s
Description
Description
Description
Description
Appendix C
Access
Updated
Read-only
Read-only
Read-only
Access
Updated
Read-only
Read/write
Read/write
Access
Updated
Read-only
Access
Updated
Read-only
Read-only
Read-only
Read-only
Read-only