Pulse Outputs
Preparation
DM Area Settings
242
6. When the stocker is full, it is moved (CIO 100.02) and only the conveyor is
lowered (absolute positioning) when stoker movement is completed (CIO
0.04).
The operation can be canceled and pulse output stopped at any point using
the Emergency Switch Input (CIO 0.01).
■ PLC Setup
Enable origin search function for pulse output 0.
Note The origin search enable setting is read when the power supply is turned ON.
Settings for PLS2(887) for Fixed-distance Positioning (D0 to D7)
Acceleration rate: 1,000 Hz/4 ms
Deceleration rate: 1,000 Hz/4 ms
Target frequency: 50,000 Hz
Number of output pulses: 10,000 pulses
Starting frequency: 0 Hz
Settings for PLS2(887) to Return to Start (D10 to D17)
Acceleration rate: 300 Hz/4 ms
Deceleration rate: 200 Hz/4 ms
Target frequency: 50,000 Hz
Setting details
Setting details
Setting details
Section 5-2
Address
Data
D0
03E8
D1
03E8
D2
C350
D3
0000
D4
2710
D5
0000
D6
0000
D7
0000
Address
Data
D10
012C
D11
00C8
D12
C350
D13
0000