5-3-12 Application Example With An Analog Output - Omron CP1L CPU UNIT - 06-2007 Operation Manual

Cp1l cpu unit
Table of Contents

Advertisement

Inverter Positioning
Modbus Communications

5-3-12 Application Example with an Analog Output

Positioning with
Trapezoidal Control
Specifications and
Operation
Note
Internal Work Addresses
Address
D1
Bits 00 to 03: Run/Stop Command
D2
Bits 00 to 15: Frequency Command Value
D10
Bits 00 to 03: Forward/Reverse Command
D15
Bit 09: Forward/Reverse Command
Settings Addresses
Address
D32200
Bits 00 to 07: Slave address
D32201
Bits 00 to 07: Function code
D32202
Bits 00 to 07: Number of communications data bytes
D32203
Bits 00 to 15: Register number of write start data
D32204
Bits 00 to 15: Number of data registers to write
D32205
Bits 08 to 15: Number of attached data bytes
D32206
Bits 00 to 07: Upper bytes of frequency command value in D2
Bit 08: Run/Stop Command
Bit 09: Forward/Reverse Command
D32207
Bits 08 to 15: Lower bytes of frequency command value in D2 ---
A26.00
Operation
Command Flag
Add the above instructions to the end of the program as a starting condition
for the ladder programming example. For error processing, refer to the ladder
program in 6-3-3 Modbus-RTU Easy Master Function and to the inverter's
manual.
When start input CIO 1.04 turns ON, 600,000 pulses are output internally for
inverter positioning 0 to turn the motor shaft.
Refer to 5-3-7 Determining the Internal Pulse Output Frequency for the for-
mula to convert the frequency and use the converted internal pulse frequency.
The number of output pulses is calculated from the encoder specifications
and the high-speed counter multiplier.
Usage
Usage
A641.00
Section 5-3
Data
01
10
09
0001
0002
04
---
Modbus-RTU Master Execution Bit
307