Planet WGS-5225-8P2SV User Manual page 322

Industrial l2+ 8-port 10/100/1000t 802.3at poe+2-port 1g/2.5g sfp wall-mount managed switch
Hide thumbs Also See for WGS-5225-8P2SV:
Table of Contents

Advertisement

The page includes the following fields:
RADIUS Authentication Server Status Overview
Object
 #
 IP Address
 Authentication
Port
 Authentication
Status
 Accounting
Port
 Accounting
Status
Buttons
Auto-refresh
: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds.
:
Click to refresh the page immediately.
Description
The RADIUS server number. Click to navigate to detailed statistics for this server.
The IP address and UDP port number (in <IP Address>:<UDP Port> notation) of this server.
UDP port number for authentication.
The current status of the server. This field takes one of the following values:
Disabled: The server is disabled.
Not Ready: The server is enabled, but IP communication is not yet up and running.
Ready: The server is enabled, IP communication is up and running, and the RADIUS
module is ready to accept access attempts.
Dead (X seconds left): Access attempts were made to this server, but it did not reply
within the configured timeout. The server has temporarily been disabled, but will get re-
enabled when the dead-time expires. The number of seconds left before this occurs is
displayed in parentheses. This state is only reachable when more than one server is
enabled.
UDP port number for accounting
The current status of the server. This field takes one of the following values:
Disabled: The server is disabled.
Not Ready: The server is enabled, but IP communication is not yet up and running.
Ready: The server is enabled, IP communication is up and running, and the RADIUS
module is ready to accept access attempts.
Dead (X seconds left): Access attempts were made to this server, but it did not reply
within the configured timeout. The server has temporarily been disabled, but will get re-
enabled when the dead-time expires. The number of seconds left before this occurs is
displayed in parentheses. This state is only reachable when more than one server is
enabled.