Clock Time Properties Data Set
The clock time properties data set is defined in the IEEE 1588 Standard. The data set is both configurable and dynamic, i.e.
the parameters can be configured for a grandmaster. In a slave clock the parameters are overwritten by the grandmasters
timing properties. The parameters are not used in the current PTP implementation.
The valid values for the Time Source parameter are:
■ 16 (0x10) ATOMIC_CLOCK
■ 32 (0x20) GPS
■ 48 (0x30) TERRESTRIAL_RADIO
■ 64 (0x40) PTP
■ 80 (0x50) NTP
■ 96 (0x60) HAND_SET
■ 144 (0x90) OTHER
■ 160 (0xA0) INTERNAL_OSCILLATOR
Object
 UtcOffset
 Valid
 leap59
 leap61
 Time Trac
 Freq Trac
 ptp Time Scale
 Time Source
 Leap Pending
 Leap Date
 Leap Type
Description
In systems whose epoch is UTC, it is the offset between TAI and UTC
When true, the value of currentUtcOffset is valid
When true, this field indicates that last minute of the current UTC day has only 59
seconds.
When true, this field indicates that last minute of the current UTC day has 61
seconds.
True if the timescale and the value of currentUtcOffset are traceable to a primary
reference.
True if the frequency determining the timescale is traceable to a primary
reference.
True if the clock timescale of the grandmaster clock and false otherwise.
The source of time used by the grandmaster clock.
When true, there is a leap event pending at the date defined by leapDate.
The date for which the leap will occur at the end of its last minute.
Date is represented as the number of days after 1970-01-01 (the latter
represented as 0).
The type of leap event i.e. leap59 or leap61.