7
|
Unit installation

7.2.2 To open the indoor unit

Installer reference guide
62
NOTICE
For a standard installation, it is usually NOT required to open the unit. Opening the
unit or any of the switch boxes is ONLY required when you want to install extra
option kits. For more information, see the installation manual of the specific option
kit, or below.
Overview
a
e
b
f
d
c
a Top panel
b User interface panel
c Front panel
d Left side panel
e Installer switch box cover
f Main switch box cover
Open
1 Remove the top panel.
T25
2 Remove the user interface panel. Open the hinges at the top and slide the
user interface panel upwards.
NOTICE
If you remove the user interface panel, also disconnect the cables from the back of
the user interface panel to prevent damage.
EWSAH/X06UD