11
|
Configuration
Installer reference guide
172
Emitter type
Additional zone
0: Underfloor
heating
1: Fancoil unit
2: Radiator
Setpoint range
For more information about Setpoint range, see
#
Code
Leaving water temperature range for the additional leaving water temperature
zone (= the leaving water temperature zone with the highest leaving water
temperature in heating operation and the lowest leaving water temperature in
cooling operation)
[3.8.1]
[9-05]
[3.8.2]
[9-06]
[3.8.3]
[9-07]
[3.8.4]
[9-08]
Control
The control type for the additional zone is read only. It is determined by the control
type of the main zone.
See
"11.5.3 Main
zone" [
#
Code
[3.9]
N/A
Ext thermostat type
Only applicable in external room thermostat control.
Also see
"11.5.3 Main
zone" [
Space heating setpoint
range [9‑05]~[9‑06]
Maximum 55°C
Maximum 65°C
Maximum 65°C
Heating minimum: 15°C~37°C
Heating maximum:
[2‑0D]=0 (emitter type additional zone =
underfloor heating)
37°C~55°C
Else: 37°C~65°C
Cooling minimum: 5°C~18°C
Cooling maximum: 18°C~22°C
4
 161].
Control:
Leaving
main zone is Leaving water.
External room thermostat if the control
type of the main zone is:
-
External room thermostat,or
-
Room thermostat.
4
 161].
Target delta T in heating
[1‑0C]
Variable (see [3.B.1])
Variable (see [3.B.1])
Variable (see [3.B.1])
"11.5.3 Main
zone" [
Description
Description
water if the control type of the
Daikin Altherma 3 WS
4P675765-1 – 2022.04
4
 161].
EWSAH/X06UD