6
|
Application guidelines

6.6.3 Power limitation process

Installer reference guide
54
Specification of the digital inputs:
-
DI1: S9S (limit 1)
-
DI2: S8S (limit 2)
-
DI3: S7S (limit 3)
-
DI4: S6S (limit 4)
Refer to the wiring diagram for more information.
Configuration
Set the power consumption control settings in [9.9] via the user interface (for the
description of all settings, see
-
Select limitation by digital inputs.
-
Select the type of limitation (power in kW or current in A).
-
Set the desired power limitation level corresponding to each digital input.
INFORMATION
In case more than 1 digital input is closed (at the same time), the digital input priority
is fixed: DI4 priority>...>DI1.
The compressor has better efficiency than the electrical heater. Therefore, the
electrical heater is limited and turned OFF first. The system limits power
consumption in the following order:
1
Limits the backup heater.
2
Turns OFF the backup heater.
3
Limits the compressor.
4
Turns OFF the compressor.
Example
If the power limitation level does NOT allow operation of full backup heater
capacity, then power consumption is limited as follows:
P
h
d
c
b
a
A
B
P
Produced heat
h
C
Consumed energy
e
A Compressor
B Backup heater
a Limited compressor operation
b Full compressor operation
c Limited backup heater operation
d Full backup heater operation
"Power consumption
C
e
4
control" [
 200]):