11
|
Configuration
Installer reference guide
156
Go to setpoint mode ...
Main zone – Heating
[2.4] Main zone > Setpoint mode
Main zone – Cooling
[2.4] Main zone > Setpoint mode
Additional zone – Heating
[3.4] Additional zone > Setpoint
mode
Additional zone – Cooling
[3.4] Additional zone > Setpoint
mode
Tank
[5.B] Tank > Setpoint mode
To change the type of weather-dependent curve
To change the type for all zones (main + additional) and for the tank, go to [2.E]
Main zone > WD curve type.
Viewing which type is selected is also possible via:
[3.C] Additional zone > WD curve type
Restriction: Only available to installers.
To change the weather-dependent curve
Zone
Main zone – Heating
Main zone – Cooling
Additional zone – Heating
Additional zone – Cooling
Tank
INFORMATION
Maximum and minimum setpoints
You cannot configure the curve with temperatures that are higher or lower than the
set maximum and minimum setpoints for that zone or for the tank. When the
maximum or minimum setpoint is reached, the curve flattens out.
To fine-tune the weather-dependent curve: slope-offset curve
The following table describes how to fine-tune the weather-dependent curve of a
zone or tank:
Set the setpoint mode to ...
WD heating, fixed cooling OR
Weather dependent
Weather dependent
WD heating, fixed cooling OR
Weather dependent
Weather dependent
Restriction: Only available to installers.
Weather dependent
Go to ...
[2.5] Main zone > Heating WD
curve
[2.6] Main zone > Cooling WD
curve
[3.5] Additional zone > Heating
WD curve
[3.6] Additional zone > Cooling
WD curve
Restriction: Only available to installers.
[5.C] Tank > WD curve
EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04

Advertisement