h
Main zone
h1 Installed room thermostat type:
Unit operation is decided based on the ambient temperature
of the dedicated Human Comfort Interface (BRC1HHDA used
as room thermostat).
Unit operation is decided by the external room thermostat
(wired or wireless).
No room thermostat installed or set. Unit operation is
decided based on the leaving water temperature regardless
of the actual room temperature and/or heating demand of
the room.
h2 Installed heat emitter type:
Underfloor heating
Fancoil unit
Radiator
21
h3
Measured room temperature
35
h4
Leaving water temperature setpoint
i
Holiday mode
Holiday mode active
j
Additional zone
j1 Installed room thermostat type:
Unit operation is decided by the external room thermostat
(wired or wireless).
No room thermostat installed or set. Unit operation is
decided based on the leaving water temperature regardless
of the actual room temperature and/or heating demand of
the room.
j2 Installed heat emitter type:
Underfloor heating
Fancoil unit
Radiator
45
j3
Leaving water temperature setpoint
k
Malfunction
A malfunction occurred.
See
"15.4.1 To display the help text in case of a
malfunction" [
(a)
If the corresponding operation (for example: space heating) is not active, the circle is
greyed out.
Description
(a)
(a)
(a)
4
 237] for more information.