Daikin Altherma 3 WS EWSAH06UD 9W Series Installer's Reference Manual page 39

Hide thumbs Also See for Altherma 3 WS EWSAH06UD 9W Series:
Table of Contents

Advertisement

Combination: Underfloor heating + Heat pump convectors – Multiple rooms
EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04
Setup
C
B
M1
M1
b
A Main leaving water temperature zone
B Room 1
C Room 2
a External room thermostat
b Heat pump convector + controller
c Remote outdoor sensor
For more information about connecting the electrical wiring to the unit, see
"9.2  Overview
of
4
actuators" [
 89].
For each room with heat  pump convectors: The heat  pump convectors are
directly connected to the indoor unit.
For each room with underfloor heating: Two shut-off valves (field supply) are
installed before the underfloor heating:
-
A shut-off valve to prevent hot water supply when the room has no heating
demand
-
A shut-off valve to prevent condensation on the floor during cooling operation
of the rooms with heat pump convectors.
For each room with heat pump convectors: The desired room temperature is set
via the controller of the heat pump convectors. There are different controllers
and setups possible for the heat pump convectors. For more information, see:
-
The installation manual of the heat pump convectors
-
The installation manual of the heat pump convector options
-
The addendum book for optional equipment
For each room with underfloor heating: The desired room temperature is set via
the external room thermostat (wired or wireless).
The user interface integrated in the indoor unit decides the space operation
mode. Mind that the operation mode on each external room thermostat and
remote controller of the heat pump convectors must be set to match the indoor
unit.
INFORMATION
To increase comfort and performance, we recommend to install the valve kit option
EKVKHPC on each heat pump convector.
A
a
electrical
connections
6
Application guidelines
|
c
for
external
and
Installer reference guide
internal
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma 3 ws ewsax06ud 9w seriesEwsah06ud 9w seriesEwsax06ud 9w seriesAltherma 3 ws

Table of Contents