10.2.3 Electricity meter

EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04
a Factory-mounted Ethernet cable
b Router (field supply)
c Smartphone with app control (field supply)
#
A
Wired
d Field-supplied Ethernet cable:
Minimum category: Cat5e
Maximum length:
-
50 m in case of Cat5e cables
-
100 m in case of Cat6 cables
B
Wireless
e Wireless bridge (field supply)
C
Power line
f Power line adapter (field supply)
g Power line (field supply)
INFORMATION
It is recommended to connect the LAN adapter to the router directly. Depending on
the wireless bridge or power line adapter model, the system might not function
properly.
NOTICE
To prevent communication problems due to cable breakdown, do NOT exceed the
minimum bend radius of the Ethernet cable.
If the LAN adapter is connected to an electricity meter, make sure it is an electrical
pulse meter.