To Close The Outdoor Unit; To Open The Indoor Unit - Daikin ETVH16UE6V7 Installer's Reference Manual

Table of Contents

Advertisement

7.2.5 To close the outdoor unit

7.2.6 To open the indoor unit

EPRA14~18D + ETVH16SU18+23E
Daikin Altherma 3 H HT F
4P644738-1D – 2023.10
NOTICE
When closing the outdoor unit cover, make sure that the tightening torque does NOT
exceed 4.1 N•m.
3 2
Overview
a
c
e
b
d
a Top panel
b User interface panel
c Switch box cover
d Front panel
e High voltage switch box cover
Open
1 Remove the top panel.
T25
2 Remove the user interface panel. Open the hinges at the top and slide the top
panel upwards.
7
4
1
3
2
4
1
Unit installation
|
Installer reference guide
71

Advertisement

Table of Contents
loading