6.6.4 Current limitation by current sensors

6.6.5 BBR16 power limitation

EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04
INFORMATION
Restriction: Current limitation by current sensors is only available for 3-phase setups
([9.3.2]=2 (Installer settings > Backup heater > Voltage = 400V, 3ph)).
NOTICE
Disconnected sensor. If you use current limitation by current sensors and one of the
sensors is disconnected, the corresponding phase is not limited anymore.
Current sensors can be used to limit the consumption of the heat pump on every
phase taking into account the set household fuse and the actual consumption of
other appliances.
Current sensors must be installed before the main fuses on each phase to make
use of this feature. This function can be useful in countries where the government
gives incentives to limit the fuse sizes.
C
i
a
CL
b
c
Ci Current input
t Time
CL Current limit corresponding to fuse size
a Current limitation active (no external load)
b External load
c Current limitation active (with external load)
d Actual current input
Setup and configuration
See:
The installation manual of the current sensors
"To perform a current sensor phase
Wires: 3×2. Use part of the cable (40 m) delivered as accessory.
See
"Power consumption
[9.9.1]=3 (Power consumption control = Current sensor)
[9.9.E] Current sensor offset
INFORMATION
Restriction: BBR16 settings are only visible when the language of the user interface is
set to Swedish.
d
t
check" [
4
control" [
 200]:
6
Application guidelines
|
4
 218]