Daikin Altherma 3 WS EWSAH06UD 9W Series Installer's Reference Manual page 262

Hide thumbs Also See for Altherma 3 WS EWSAH06UD 9W Series:
Table of Contents

Advertisement

8/11
Field settings table
Breadcrumb
Field code
Setting name
9.I
[2-0C]
What emitter type is connected to the main LWT zone?
9.I
[2-0D]
What emitter type is connected to the additional LWT zone?
9.I
[2-0E]
What is the maximum allowed current over the heatpump ?
9.I
[3-00]
Is auto restart of the unit allowed?
9.I
[3-01]
--
9.I
[3-02]
--
9.I
[3-03]
--
9.I
[3-04]
--
9.I
[3-05]
--
9.I
[3-06]
What is the maximum desired room temperature in heating?
9.I
[3-07]
What is the mimimum desired room temperature in heating?
9.I
[3-08]
What is the maximum desired room temperature in cooling?
9.I
[3-09]
What is the minimum desired room temperature in cooling?
9.I
[3-0A]
Waterloop Valve Opening Frequency
9.I
[3-0B]
Waterloop Valve Opening Duration
9.I
[4-00]
What is the BUH operation mode?
9.I
[4-01]
Which electric heater has priority?
9.I
[4-02]
Below which outdoor temperature is heating allowed?
9.I
[4-03]
--
9.I
[4-04]
Water pipe freeze prevention
9.I
[4-05]
--
9.I
[4-06]
Emergency setting
9.I
[4-07]
Maximum BUH capacity
9.I
[4-08]
Which power limitation mode is required on the system?
9.I
[4-09]
Which power limitation type is required?
9.I
[4-0A]
--
9.I
[4-0B]
Automatic cooling/heating changeover hysteresis.
9.I
[4-0D]
Automatic cooling/heating changeover offset.
9.I
[4-0E]
Current sensor offset
9.I
[5-00]
Equilibrium: Deactivate backup heater (or external backup heat source in case of a
bivalent system) above the equilibrium temperature for space heating?
9.I
[5-01]
What is the equilibrium temperature for the building?
9.I
[5-02]
Space heating priority.
9.I
[5-03]
Space heating priority temperature.
9.I
[5-04]
--
9.I
[5-05]
What is the requested limit for DI1?
9.I
[5-06]
What is the requested limit for DI2?
9.I
[5-07]
What is the requested limit for DI3?
9.I
[5-08]
What is the requested limit for DI4?
9.I
[5-09]
What is the requested limit for DI1?
9.I
[5-0A]
What is the requested limit for DI2?
9.I
[5-0B]
What is the requested limit for DI3?
9.I
[5-0C]
What is the requested limit for DI4?
9.I
[5-0D]
Backup heater voltage
9.I
[5-0E]
--
9.I
[6-00]
The temperature difference determining the heat pump ON temperature.
9.I
[6-01]
The temperature difference determining the heat pump OFF temperature.
9.I
[6-02]
--
9.I
[6-03]
--
9.I
[6-04]
--
9.I
[6-05]
--
9.I
[6-06]
--
9.I
[6-07]
--
4P675763-1 - 2021.10
Range, step
Default value
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
R/W
20~50 A, step: 1 A
50 A
R/W
0: No
1: Yes
0
1
4
2
1
R/W
18~30°C, step: 0,5°C
30°C
R/W
12~18°C, step: 0,5°C
12°C
R/W
25~35°C, step: 0,5°C
35°C
R/W
15~25°C, step: 0,5°C
15°C
R/W
0: OFF
1: Every Day
2: Every Week
R/W
30~120 minutes, step: 30 minutes
60 minutes
R/W
0: Disabled
1: Enabled
2: Only DHW
R/W
0: None
1: BSH
2: BUH
R/W
14~35°C, step: 1°C
16°C
3
R/O
0: Intermittent
1: continuous
2: Disabled
0
R/W
0: Manual
1: Automatic (normal SH/ DHW ON)
2: Auto red SH/ DHW ON
3: Auto red SH/ DHW OFF
4: Auto normal SH/ DHW OFF
R/W
[5-0D]=2: 0~9 kW, step: 1 kW
9 kW
[5-0D]≠2: 0~6 kW, step: 1 kW
6 kW
R/W
0: No limitation
1: Continuous
2: Digital inputs
3: Current sensors
R/W
0: Current
1: Power
1
R/W
1~10°C, step: 0,5°C
1°C
R/W
1~10°C, step: 0,5°C
3°C
R/W
-6~6 A, step: 0,5 A
0 A
R/W
0: No
1: Yes
R/W
-15~35°C, step: 1°C
0°C
R/W
0: Disabled
1: Enabled
R/W
-15~35°C, step: 1°C
0°C
10
R/W
0~50 A, step: 1 A
16 A
R/W
0~50 A, step: 1 A
16 A
R/W
0~50 A, step: 1 A
16 A
R/W
0~50 A, step: 1 A
16 A
R/W
0~20 kW, step: 0,5 kW
5 kW
R/W
0~20 kW, step: 0,5 kW
5 kW
R/W
0~20 kW, step: 0,5 kW
5 kW
R/W
0~20 kW, step: 0,5 kW
5 kW
R/W
0: 230V, 1~
2: 400V, 3~
1
R/W
2~20°C, step: 1°C
6°C
R/W
0~10°C, step: 1°C
2°C
0
3
6
0
0
0
Installer setting at variance with
default value
Date
Value