Daikin Altherma 3 WS EWSAH06UD 9W Series Installer's Reference Manual page 37

Hide thumbs Also See for Altherma 3 WS EWSAH06UD 9W Series:
Table of Contents

Advertisement

Heat pump convectors – Multiple rooms
EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04
For more information about connecting the electrical wiring to the unit, see
"9.2  Overview
of
4
actuators" [
 89].
For each room, a shut-off valve (field supplied) is installed to avoid leaving water
supply when there is no heating or cooling demand.
A bypass valve must be installed to make water recirculation possible when all
shut-off valves are closed.
The user interface integrated in the indoor unit decides the space operation
mode. Mind that the operation mode on each room thermostat must be set to
match the indoor unit.
The room thermostats are connected to the shut-off valves, but do NOT have to
be connected to the indoor unit. The indoor unit will supply leaving water all the
time, with the possibility to program a leaving water schedule.
Configuration
Setting
Unit temperature control:
#: [2.9]
Code: [C-07]
Number of water temperature zones:
#: [4.4]
Code: [7-02]
Benefits
Compared with underfloor heating or radiators for one room:
Comfort. You can set the desired room temperature, including schedules, for
each room via the room thermostats.
Setup
C
B
a
a
A Main leaving water temperature zone
B Room 1
C Room 2
a Heat pump convectors + controllers
b Remote outdoor sensor
electrical
connections
0 (Leaving water): Unit operation is
decided based on the leaving water
temperature.
0 (Single zone): Main
A
6
Application guidelines
|
for
external
and
Value
b
Installer reference guide
internal
37