Electrical connection diagram
For more details, please check the unit wiring.
POWER SUPPLY
Only for preferential kWh rate unit power supply installation
normal kWh rate power supply for indoor unit: 230 V + earth
POWER SUPPLY
1
Only for single cable power supply
2
Only for combined 3F power supply installation
Backup heater & compressor power supply:
400 V + earth
2
Only for combined 1F power supply installation
Backup heater & compressor power supply:
230 V + earth
1
Only for dual cable power supply
3
Only for split 3F/1F power supply installation
Backup heater power supply: 400 V + earth
Only with EKGSPOWCAB
Compressor power supply: 230 V + earth
3
Only for split 1F/1F power supply installation
Backup heater power supply: 230 V + earth
Only with EKGSPOWCAB
Compressor power supply: 230 V + earth
FIELD SUPPLY
Only for preferential kWh rate power supply installation
Preferential kWh rate power supply contact
4
Safety thermostat Q4L
4
OPTIONAL PART
Only for EKCSENS
Current sensors
FIELD SUPPLY
Drain pump
Only for pressure loss detection
Brine low pressure switch S1PL
FIELD SUPPLY
Power limitation demand input 1
Power limitation demand input 2
Power limitation demand input 3
Power limitation demand input 4
EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04
STANDARD PARTS
INDOOR UNIT
3 core
X2M: 5-6-earth
5 core
F1B
X21Y
5 core
F1B
X21Y
5 core
F1B
X21Y
3 core
F2B
X22YB
5 core
F1B
X21Y
3 core
F2B
X22YB
2 core
2x0.75
X5M: 9-10
4 core
X5M: 13-14-15-16
signal
2 core
X2M: 30-31
230 V
2 core
A16P: X13A
signal
Only for EKRP1AHTA
2 core
A8P: X801M: 1-5
signal
2 core
A8P: X801M: 2-5
signal
2 core
A8P: X801M: 3-5
signal
2 core
A8P: X801M: 4-5
signal
X12Y: 1-2
Only for EKRP1HB*
A4P: Y1
X2M: 14a
Alarm output
A4P: X1-X2
Changeover to external heat
source output
A4P: Y2
X2M: 14a
Space heating On/OFF output
X2M: 1-2
NO valve: X2M: 21-28
NC valve: X2M: 21-29
X5M: 5-6
X5M: 3-4
Only for KRCS01-1
X5M: 7-8
EXTERNAL ROOM THERMOSTAT / HEAT PUMP CONVECTOR
(main and/or additional zone)
5
3 core for C/H operation
2 core for H only operation
main: X2M: 30-34-35
add: X2M: 30-34a-35a
5
5 core for C/H operation
4 core for H only operation
main: X2M: 30-31-34-35
add: X2M: 30-31-34a-35a
5
main: X2M: 3-4-30-35
add: X2M: 3-4-30-35a
X5M: 11-12
communication
A15P: X4A
17
Technical data
|
Note:
- In case of signal cable: keep minimum distance to power cables >5 cm
2 core
Outdoor ambient sensor EKRSCA1
signal
2 core
Alarm indication
230 V
2 core
External heat source (e.g. boiler)
signal
2 core
Space heating On/OFF output
230 V
2 core
Circulation pump for domestic hot water
230 V
SHUT-OFF VALVE
2 core
Main zone shut-off valve
230 V
2 core
Electricity meter pulse input 1
signal
2 core
Electricity meter pulse input 2
signal
2 core
External indoor ambient thermistor
signal
Only for EKRTWA
(wired room thermostat)
A3P: X1M: C-com-H
signal
Only for EKRTR1/EKRTRB
(wireless room thermostat)
A4P: X1M: C-com-H
X2M: L-N
signal
R2T External sensor
(Floor or ambient)
Only for heat pump convector
4 core
A3P
signal
2 core
Only for BRC1HHDA*
2x0.75
A2P: P1-P2 user interface
Router for LAN adapter
ethernet
FIELD SUPPLY
OPTIONAL PART
OPTIONAL PART
EKRTR1
EKRTRB
A3P: X1M: 1-2
Only for EKRTETS
OPTIONAL PART
FIELD SUPPLY
4D137622
Installer reference guide
251