Daikin Altherma 3 WS EWSAH06UD 9W Series Installer's Reference Manual page 200

Hide thumbs Also See for Altherma 3 WS EWSAH06UD 9W Series:
Table of Contents

Advertisement

11
|
Configuration
Power consumption control
Installer reference guide
200
#
Code
[9.8.2]
[D-00]
[9.8.3]
[D-05]
Allowed heaters during preferential kWh rate power supply
Do NOT use 1 or 3. Setting [D-00] to 1 or 3 when [D-01] is set to 1 or 2 will reset
[D-00] back to 0, as the system does not have a booster heater. Only set [D-00] to
the values in the table below:
[D‑00]
0
2
Power consumption control
See
"6  Application
guidelines"  [
functionality.
#
[9.9.1]
[4-08]
Allow heater: Which heaters are allowed to
operate during preferential kWh rate power
supply?
0 No: None
1 Only BSH: Booster heater only
2 Only BUH: Backup heater only
3 All: All heaters
See table below.
Setting 2 is only meaningful if the preferential
kWh rate power supply is of type 1 or indoor unit
is connected to a normal kWh rate power supply
(via X2M/5‑6) and the backup heater is NOT
connected to the preferential kWh rate power
supply.
Allow pump:
0 No: Pump is forced off
1 Yes: No limitation
Backup heater
Forced OFF
Allowed
4
  29] for detailed information about this
Code
Power consumption control:
0 No: Disabled.
1 Continuous: Enabled: You can set one
power limitation value (in A or kW) to which
the system power consumption will be
limited for all the time.
2 Inputs: Enabled: You can set up to four
different power limitation values (in A or kW)
to which the system power consumption will
be limited when the corresponding digital
input asks.
3 Current sensor: Enabled: You can set a
current limitation value (in A) to which the
household current will be limited.
Description
Compressor
Forced OFF
Description
EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04