Daikin Altherma 3 WS EWSAH06UD 9W Series Installer's Reference Manual page 202

Hide thumbs Also See for Altherma 3 WS EWSAH06UD 9W Series:
Table of Contents

Advertisement

11
|
Configuration
Energy metering
Installer reference guide
202
#
[9.9.E]
[4-0E]
Priority heater
This setting defines the priority of the electrical heaters depending on applicable
limitation. As no booster heater is present, the backup heater will always be
prioritised.
#
[9.9.D]
[4-01]
Energy metering
If energy metering is performed by the use of external power meters, configure the
settings as described below. Select the pulse frequency output of each power
meter in accordance with the power meter specifications. It is possible to connect
up to 2 power meters with different pulse frequencies. If only 1 or no power meter
is used, select 'None' to indicate the corresponding pulse input is NOT used.
#
Code
[9.A.1]
[D‑08]
[9.A.2]
[D‑09]
Code
Current sensor offset: Offset on the
household current measured by the current
sensors.
–6 A~6 A, step 0.5 A
Code
Priority heater:
0 None : The backup heater is prioritised.
1 Booster
setting will be reverted back to 0=None and
the backup heater will be prioritised.
2 Backup
prioritised.
Electricity meter 1:
0 None: NOT installed
1 1/10kWh: Installed
2 1/kWh: Installed
3 10/kWh: Installed
4 100/kWh: Installed
5 1000/kWh: Installed
Electricity meter 2:
0 None: NOT installed
1 1/10kWh: Installed
2 1/kWh: Installed
3 10/kWh: Installed
4 100/kWh: Installed
5 1000/kWh: Installed
Description
Description
heater: After restart, the
heater: The backup heater is
Description
Daikin Altherma 3 WS
4P675765-1 – 2022.04
EWSAH/X06UD