Daikin Altherma 3 WS EWSAH06UD 9W Series Installer's Reference Manual page 164

Hide thumbs Also See for Altherma 3 WS EWSAH06UD 9W Series:
Table of Contents

Advertisement

11
|
Configuration
Installer reference guide
164
#
Code
[2.7]
[2‑0C]
The setting Emitter type influences the space heating setpoint range and the
target delta T in heating as follows:
Emitter type Main
zone
0: Underfloor
heating
1: Fancoil unit
2: Radiator
NOTICE
The maximum setpoint in space heating depends on the emitter type as can be seen
in above table. If there are 2 water temperature zones, then the maximum setpoint
is the maximum of the 2 zones.
NOTICE
NOT configuring the system in the following way can cause damage to the heat
emitters. If there are 2 zones, it is important that in heating:
the zone with the lowest water temperature is configured as the main zone, and
the zone with the highest water temperature is configured as the additional zone.
NOTICE
If there are 2 zones and the emitter types are wrongly configured, water of high
temperature can be sent towards a low temperature emitter (underfloor heating). To
avoid this:
Install an aquastat/thermostatic valve to avoid too high temperatures towards a
low temperature emitter.
Make sure you set the emitter types for the main zone [2.7] and for the
additional zone [3.7] correctly in accordance with the connected emitter.
Setpoint range
To prevent a wrong (i.e. too hot or too cold) leaving water temperature for the
main leaving water temperature zone, limit its temperature range.
NOTICE
In case of a floor heating application it is important to limit the:
maximum leaving water temperature at heating operation according to the
specifications of the floor heating installation.
the minimum leaving water temperature at cooling operation to 18~20°C to
prevent condensation on the floor.
Emitter type:
0: Underfloor heating
1: Fancoil unit
2: Radiator
Space heating setpoint
range [9‑01]~[9‑00]
Maximum 55°C
Maximum 65°C
Maximum 65°C
Description
Target delta T in heating
[1‑0B]
Variable (see [2.B.1])
Variable (see [2.B.1])
Variable (see [2.B.1])
EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma 3 ws ewsax06ud 9w seriesEwsah06ud 9w seriesEwsax06ud 9w seriesAltherma 3 ws

Table of Contents