10.1.1 System layout
EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04
Status LEDs
LED
LD1
Indication of power to the
adapter, and of normal
operation.
LD2
Indication of TCP/IP
communication with the
router.
LD3
Indication of communication
with the indoor unit.
LD4
Indication of Smart Grid
activity.
INFORMATION
▪
The DIP switch is used to configure the system. For more information, see
"10.4 Configuration – LAN
▪
When the LAN adapter performs a Smart Grid compatibility check, LD4 flashes.
This is NOT erroneous behaviour. After a successful check, LD4 will either stay ON
or go OFF. When it keeps flashing for more than 30 minutes, the compatibility
check failed, and NO Smart Grid operation is possible.
Integrating the LAN adapter into the heat pump system allows for the following
applications:
▪
App control (only)
▪
Smart Grid application (only)
▪
App control + Smart Grid application
Description
4
adapter" [
122].
10
LAN adapter
|
Behaviour
▪
LED
flashing:
operation.
▪
LED
NOT
flashing:
operation.
▪
LED
ON:
communication.
▪
LED flashing: communication
problem.
▪
LED
ON:
communication.
▪
LED flashing: communication
problem.
▪
LED ON: system running in
the
"Recommended
"Forced ON", or "Forced OFF"
Smart Grid operation mode.
▪
LED OFF: system running in
the
"Normal
operation"
Smart Grid operation mode,
or
operating
in
operation conditions (space
heating/cooling,
production
of domestic hot water).
▪
LED flashing: LAN adapter
performing a Smart Grid
compatibility check.
Installer reference guide
normal
no
normal
normal
ON",
normal
111