9
|
Electrical installation
Installer reference guide
90
Item
Thermostat for passive
cooling
LAN adapter connections
Room thermostat (wired or
wireless)
Heat pump convector
Remote indoor sensor
Description
See
"9.2.12 To connect the thermostat for passive
4
cooling" [
109].
4
See
"10 LAN
adapter" [
See:
▪
Installation manual of the room thermostat
(wired or wireless)
▪
Addendum book for optional equipment
Wires for wired room thermostat: (3 for
cooling/heating operation; 2 for heating only
operation)×0.75 mm²
Wires for wireless room thermostat: (5 for
cooling/heating operation; 4 for heating only
operation)×0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪
[2.9] Control
▪
[2.A] Ext thermostat type
For the additional zone:
▪
[3.A] Ext thermostat type
▪
[3.9] (read-only) Control
See:
▪
Installation manual of the heat pump
convectors
▪
Addendum book for optional equipment
Wires: 4×0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪
[2.9] Control
▪
[2.A] Ext thermostat type
For the additional zone:
▪
[3.A] Ext thermostat type
▪
[3.9] (read-only) Control
See:
▪
Installation manual of the remote indoor
sensor
▪
Addendum book for optional equipment
Wires: 2×0.75 mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
110].
EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04