7. Lift the heat sink from the system.
Figure 112. Removing the liquid cooling heat sink modules
Next steps
1. If you are uninstalling a faulty heat sink,

Removing the processor

Prerequisites
WARNING:
The heat sink may be hot to touch for some time after the system has been powered off. Allow the
heat sink to cool before removing it.
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the heat
sink.
CAUTION:
You may find the CMOS battery loss or CMOS checksum error is displayed during the first instance
of powering on the system after the processor or system board replacement which is expected. To fix, go to set
up option to configure the system settings.
Steps
1. Using a Torx #T20 screwdriver, loosen the middle screw to release the retention frame. Hold and lift the retention frame
upwards and rotate it slightly pass the vertical position(105 degrees).
NOTE:
The spring loading will keep the retention frame at its "open" position.
150
Installing and removing system components
replace the liquid cooling heat sink
Safety
instructions.
Before working inside your
modules, else
system.
remove the
processor.