Edit->Redundancy Screen - Geographical Redundancy - Teledyne QMultiFlex-400 Installation And Operating Handbook

Mcpc/scpc hub
Table of Contents

Advertisement

QMultiFlex-400™ Installation and Operating Handbook
Once the modem is in Maintenance mode, the Switch to maintenance button is replaced
with a Switch to service button, which can be used to reverse the process by making the
modem available to come online.
The 1-for-N address and Polarisation Switch options are used in 1 for N systems and are
covered in the Q-NET™ PDQS Redundancy Switch Installation and Operating Handbook
available at www.ParadiseData.com
6.2.26.1 Edit->Redundancy Screen – Geographical Redundancy
If the Geo Redundancy option is activated in the modem, the Redundancy Screen will look
like the following (default settings shown).
Figure 6-55 Redundancy Screen – with Geo Redundancy Option
Monitor IP address: IP address of a very high availability device, preferably located at the
NOC e.g. HSRP or VRRP address of a redundant switch pair. If pings to this IP address
fail, a Geo switchover will occur.
Peer IP address 1: This should be the M&C IP address of the first peer modem at the other
geo site.
Peer IP address 2: This should be the M&C IP address of the second peer modem at the
other geo site. If there is only one modem, leave set to 0.0.0.0